Refilling & Bleeding System

  1. Fill reservoir to correct level. Let oil settle for 2 minutes. Start engine and run for 4-5 seconds. Check reservoir. Add oil (if necessary). Repeat procedure until level in reservoir remains constant.
  2. Raise vehicle with both front wheels off ground. Start engine and increase engine speed to 1500 RPM. Turn wheels right and left, lightly contacting stops. Check fluid level. Add fluid (if necessary).
  3. Lower vehicle. Turn wheels right and left. Check fluid level. Add fluid (if necessary). If oil is foamy, proceed to step 4).
  4. Turn off engine and let vehicle sit for a few minutes. Repeat steps 1) through 3) with wheels off ground. Check fluid for air in system. If fluid level is low and air is apparent, repeat complete procedure.