LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 1988 >> Forward Control 5.7 M, Automatic, 475/M40 >> Repair and Diagnosis >> Electrical >> Charging Systems >> Alternator - Models W/Integral Regulator >> Bench Testing >> Si Series >> Diode Trio Test

Diode Trio Test

  1. Remove diode trio from end frame. Connect an ohmmeter to single connector and to one of the 3 connectors. See Fig 1. Note reading and reverse leads. If readings are the same, replace diode trio.
  2. A good diode trio will give a high and low reading. Repeat tests between single connector and each of the 3 connectors. Connect ohmmeter to each of the 3 connectors. If any readings are zero, replace diode trio.
NOTE: Before replacing diode trio, also check rectifier bridge. DO NOT  use high voltage, such as 110-volt test light, when testing diode trio.
Fig 1: Bench Testing Diode Trio
G11704