Float Level Too Low
- a) Lift out metering rods. Remove solenoid connector screws.
- b) Turn lean mixture solenoid screw clockwise, counting and recording number of turns required to lightly seat screw in float bowl.
- c) Turn screw counterclockwise and remove. Lift solenoid and connector from float bowl.
- d) Remove float and bend arm up to adjust. Make sure float is correctly aligned after adjustment.
- e) Reinstall components in reverse order from which they were removed. Back out solenoid mixture screw number of turns noted in step b.