Pick-up Coil

  1. Connect external vacuum source to distributor vacuum advance. Connect ohmmeter leads as shown by meter "A". See Figure. Apply vacuum and operate advance unit through entire range while observing ohmmeter. Reading should be infinity at all times. If ohmmeter reading fluctuates, replace pick-up coil.