LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2024 >> LYRIQ Tech, RWD >> Repair and Diagnosis >> Quick Lookups >> Technical Bulletins >> Technical Service Bulletins >> Other Variant >> Engine Control Systems >> U018B Set Current In One Or More Modules (PIC6583D)

U018B Set Current In One Or More Modules (PIC6583D)

WARNING: This page is about the LYRIQ Luxury, AWD, which is a different variant/trim than selected.
Publication date: 2025-05-05
Reference number: PIC6583D
Supersedes refnos: PIC6583, PIC6583A, PIC6583B, PIC6583C

U018B SET CURRENT IN ONE OR MORE MODULES

U018B SET CURRENT IN ONE OR MORE MODULES

TECHNICAL SERVICE BULLETIN

Reference Number(s): PIC6583D, Date of Issue:  May 5, 2025

SERVICE INFORMATION

Brand: Model: Model Year: VIN: Engine: Transmission:
from to from to
Cadillac LYRIQ 2023-2025 All All All All
Involved Region or Country  North America, Middle East, Australia, New Zealand, Europe, Israel, Japan and S. Korea
Condition  A customer may comment one or more of the following concerns; NFC key card inop (Model Year 2025 only), Service vehicle soon light, Service OnStar message.
Cause  K183 UHF module logic locked

CORRECTION

Perform a global reset by disconnecting 12V battery for 30 minutes, using Document ID: 6307865 Battery Negative Cable Disconnection and Connection.

If the K183 (UHF) module recovers from being offline, then the K183 will require the latest K183 24.169.1.3 or greater software to be flashed into the module, perform Vehicle Wide Programming, refer to 24-NA-113 VEHICLE WIDE PROGRAMMING INSTRUCTIONS .

If the 12V battery reset does not recover the K183 offline issue, then K183 module replacement in required. In which service will install a new K183 at the latest K183 24.169.1.3 or greater release.

WARRANTY INFORMATION

For vehicles repaired under the Bumper-to-Bumper coverage (Canada Base Warranty coverage), use the following labor operation. Reference the Applicable Warranties section of Investigate Vehicle History (IVH) for coverage information.

Labor Operation Description Labor Time
*6480028 System Reset 0.5
2819505 Vehicle Wide Programming Use Published Labor Time
6430600 UHF Short Range Low Energy Remote Control Access Transceiver Replacement Use Published Labor Time
*This is a unique Labor Operation for Bulletin use only.
Version  5
Modified  10/25/2024 - Created on.
02/25/2025 - Updated correction.
03/25/2025 - Updated correction and Labor operation.
04/11/2025 - Updated Unique labor operation.
05/05/2025 - Region and Correction.