Removal Procedure
- Disconnect the battery negative cable. Battery Negative Cable Disconnection and Connection
- Remove the oil fill cap.
Intake Manifold Cover Bolt (1) - Remove
- Disengage the intake manifold cover (2) from the intake manifold.
- Install the oil filler cap after removal of the intake manifold cover to prevent debris from falling into the engine.
Air Cleaner Outlet Duct Clamp (1) - Loosen [2x]
- Air Cleaner Outlet Front Duct (2) - Remove
Intake Air Baffle Retainer (1) - Remove [9x]
- Intake Air Splash Shield (2) - Remove
Intake Air Duct Retainer (1) - Remove
- Intake Air Duct (2) - Remove
Disconnect the mass airflow sensor electrical connector.
- Air Cleaner Housing Cover Bolt (1) - Remove [3x]
- Air Cleaner Upper Housing (2) - Remove
- Remove all retainers from air cleaner lower housing.
Electrical Connector (1) @Air Cleaner Lower Housing - Remove
Engine Wiring Harness Fuse Block Bracket Bolt (1) - Remove
- Accessory Wiring Junction Block (2) - Reposition
Air Cleaner Nut (1) - Remove
Air Cleaner Lower Housing (1) - Remove
Charge Air Cooler Coolant Reservoir Bolt (1) - Remove
- Charge Air Cooler Coolant Reservoir (2) - Position aside
Air Conditioning Compressor and Condenser Hose Clip (2) - Unclip [4x]
- Air Conditioning Compressor and Condenser Hose (1) - Position aside
- Detach harness retainers as necessary.
Transmission Fluid Cooler Pipe Clip (1) @Engine Coolant Fan Rear Shroud - Remove [2x]
Engine Front Cover Bolt (1) - Remove
- Engine Front Cover (2) - Remove
Rotate the accessory drive primary belt tensioner (1) clockwise to release the drive belt tension.
- Slide the accessory drive primary belt (2) off of the belt idler pulley and slowly release the accessory drive primary belt tensioner (1).
Drive Belt Idler Pulley (1) - Remove
Radiator Inlet Hose Clip (1) - Unclip
- Engine Wiring Harness Retainer (2) - Remove [2x]
- Engine Wiring Harness Bracket Bolt (3) - Remove
- Engine Wiring Harness Bracket (4) - Remove
Electrical Connector (1) - Disconnect
Battery Positive Cable Nut (1) @Generator (4) - Remove
- Generator Battery Jumper Cable (2) - Remove
Generator Bolt (1) - Loosen until disengaged
- Generator Bolt (2) - Remove
- Reposition hoses and wiring harness as needed.
Generator (1) - Remove
Generator Bolt (1) - Remove