Installation Procedure
Install the EBCM (1) to the BPMV.
- CAUTION:
Refer to Fastener Caution .
Install the EBCM bolts (1) and tighten to 6 N.m (53 lb in).
- Connect the EBCM electrical connector.
Install the windshield washer solvent container filler tube (1). Windshield Washer Solvent Container Filler Tube Replacement (Sedan with CE1)Windshield Washer Solvent Container Filler Tube Replacement (Sedan with CE4)Windshield Washer Solvent Container Filler Tube Replacement (Coupe)
- Program the EBCM. Control Module References