LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2017 >> XT5 Base >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Controls And Fuel - 3.6L (LGX) - Repair Instructions >> Repair Instructions >> Air Cleaner Outlet Duct Replacement

Air Cleaner Outlet Duct Replacement

Fig 1: Air Cleaner Outlet Duct
GM4310615Courtesy of GENERAL MOTORS COMPANY
Callout Component Name
Preliminary Procedure 
Remove Positive Crankcase Ventilation Hose/Pipe/Tube. Refer to Positive Crankcase Ventilation Hose/Pipe/Tube Replacement (Air Outlet Duct to Camshaft Covers)Positive Crankcase Ventilation Hose/Pipe/Tube Replacement (Air Outlet Duct to PCV Oil Separator)
1 Air Cleaner Outlet Duct Fastener
CAUTION:

Refer to Fastener Caution .


Tighten 
9 N.m (80 lb in)
2 Air Cleaner Outlet Duct Clamp (Qty: 2)
Tighten 
4 N.m (35 lb in)
3 Air Cleaner Outlet Duct
Procedure 
Lift up to remove from retainers.