Calibration (UGN and Escalade): Notes
New modules must be SPS programmed prior to calibration, refer to Control Module References
The calibration process for the front view camera system is necessary when a front view camera module is replaced by a new one. This process is required when only replacing the windshield and the frontview camera module has been mounted again properly. This process shall be completed within 3-5 minutes when the correct driving conditions are met. If conditions are not met, the front view camera module shall continuously run the service point calibration until successfully completed. This process shall work across ignition cycles and shall not be required to be re-initialized at start up. If the Lane Departure Warning Switch is pressed during calibration, the indictor will flash momentarily and then stay out - this is normal operation.
Once SPS programming is complete, it is necessary to initiate the calibration using a scantool. During this time the "Service Driver Assist" service message will be displayed.
To calibrate the front camera, operate the vehicle in the following conditions until the calibration is complete:
- Clean windshield.
- Avoid lane changes.
- Maintain vehicle speeds between 56-90 km/h (35-56 MPH).
- Ensure the road contains visible references (well defined lane markings, curbs, etc.).