Calibration Procedure
- Apply the parking brake.NOTE: It is necessary to have the scan tool connected during the entire process. Do not back out of the screen or press any other buttons.
- Place the transmission in Park (if applicable)
- Install scan tool
- Navigate to the module diagnostics menu
- Select Frontview Camera Module
- Select Configuration/ Reset Functions menu Item
- Select the Frontview Camera Learn procedure and follow the directions displayed on the screen.
- Do not disconnect the scan tool, drive the vehicle to complete calibration.
Once the procedure is complete, the service message will turn off and normal operation will resume. Shortly after the green ready to assist light should turn on as long as all conditions are met for normal operation. The system is then ready to assist.