LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2012 >> Escalade EXT >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Controls/Fuel - 5.3L, 6.0L, 6.2L - Repair Instructions >> Repair Instructions >> Air Cleaner Resonator Outlet Duct Replacement >> Removal Procedure

Removal Procedure

    Fig 1: View Of PCV Tube
    GM1696754Courtesy of GENERAL MOTORS COMPANY
  1. Remove the intake manifold sight shield. Refer to Upper Intake Manifold Sight Shield Replacement .
  2. Remove the positive crankcase ventilation (PCV) line (1) from the air cleaner outlet duct.
  3. Fig 2: View Of Air Cleaner Outlet Ducts
    GM1696567Courtesy of GENERAL MOTORS COMPANY
  4. Remove the radiator inlet hose clamp retainer from the outlet duct.
  5. Loosen the air cleaner outlet duct clamp (1) at the mass air flow (MAF)/intake air temperature (IAT) sensor.
  6. Loosen the air cleaner outlet duct clamp (2) at the throttle body.
  7. Lift up the air cleaner outlet duct at the resonator tab in order to separate the resonator from the stud on the intake manifold.
  8. Remove the air cleaner outlet duct from the throttle body and MAF/IAT sensor.