Circuit/System Verification

  1. Ignition ON, observe the scan tool ECM PNP Switch parameter while shifting the transmission through each range. The reading should change between Park/Neutral and In Gear.
    • If not the specified value, refer to PNP Switch Malfunction.
  2. Command the Starter Relay ON with the scan tool, or turn the ignition switch to the START position. The starter solenoid should click and the engine should crank.