Circuit/System Testing
- Ignition ON, verify that no generator or battery current sensor DTCs are set that would cause a charging system concern.
- Ignition OFF, measure the voltage across the battery terminals. The voltage should read 12.0 volts or greater at room temperature.
- Connect a carbon pile tester to the battery.
- Start the engine and increase the engine speed to 2,500 RPM. Observe the voltage reading on the tester. The voltage should read between 12.6-15.0 volts.
- If not within specified range, replace the generator.
- Adjust the carbon pile tester to the specified load test output value, refer to Generator Usage .
- If not within specified value, replace the generator.