Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the information center telltale assembly.
- Ignition ON, test for 9.0-12.5 V between the supply voltage circuit terminal A and ground.
- If less than the specified range, test the supply voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the object alarm module.
- If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the object alarm module.
- Command the appropriate LED ON with a scan tool and test for 10.5-12.5 V between the appropriate control circuit listed below and ground:
- Amber 1 LED - terminal B
- Amber 2 LED - terminal C
- Red LED - terminal D
- If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the object alarm module.
- If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the object alarm module.
- If all circuits test normal, test or replace the information center telltale assembly.