Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the shift lock control solenoid.
- Ignition ON, test between the Ignition voltage circuit terminal E and ground.
- If the test lamp did not illuminate, test the B+ circuit for a short to ground or open/high resistance. If the circuit tests normal, test or replace the shift lock control solenoid.
- Install a test lamp between the B+ circuit terminal E and control circuit terminal K.
- Ignition ON, depress and release the brake pedal several times. The test lamp should turn ON and OFF as commanded.
- If the test lamp is always ON, test the control circuit for short to ground.If the circuit tests normal, replace the RCDLR.
- If the test lamp is always OFF, test the control circuit for an open/high resistance or short to voltage. If the circuit test normal, replace the RCDLR.
- Test or replace the shift lock control solenoid.