Instrument Panel Module (IPM) Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Turn the Ignition ON, with the Engine OFF
Battery Voltage Signal Load Management Volts 12.6 V
Column Lock Relay Outputs Enabled/Disabled Enabled
Telescope Forward Switch Inputs Active/Inactive Inactive
Telescope Rearward Switch Inputs Active/Inactive Inactive
Tilt Down Switch Inputs Active/Inactive Inactive
Tilt Up Switch Inputs Active/Inactive Inactive
Memory Seat Module (MSM) Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Default Telescope Exit Position Telescope Sensor Volts 3.76 V
Default Tilt Exit Position Tilt Sensor Volts 3.76 V
Driver 1 Memorized Position Telescope Sensor Volts/Counts 0.7-3.2 V (45-157 Counts)
Driver 1 Memorized Position Tilt Sensor Volts/Counts 1.6-4.2 V (88-207 Counts)
Driver 2 Memorized Position Telescope Sensor Volts/Counts 0.7-3.2 V (45-157 Counts)
Driver 2 Memorized Position Tilt Sensor Volts/Counts 1.6-4.2 V (88-207 Counts)
Memory 1 Telescope Exit Position Telescope Sensor Volts Varies
Memory 1 Tilt Exit Position Tilt Sensor Volts Varies
Memory 2 Telescope Exit Position Telescope Sensor Volts Varies
Memory 2 Tilt Exit Position Tilt Sensor Volts Varies
Telescope Forward Command Telescope Sensor On/Off Off
Telescope Rearward Command Telescope Sensor On/Off Off
Telescope Sensor Telescope Sensor Volts/Counts 0.7-3.2 V (45-157 Counts)
Telescope Soft Stops Learned Telescope Sensor Yes/No Yes
Tilt Down Command Tilt Sensor On/Off Off
Tilt Sensor Tilt Sensor Volts/Counts 1.6-4.2 V (88-207 Counts)
Tilt Soft Stops Learned Tilt Sensor Yes/No Yes
Tilt Up Command Tilt Sensor On/Off Off
Steering Column Lock Control Module (SCLCM) Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Column Lock Relay Command BCM On/Off On
Column Lock Relay Signal BCM On/Off On