Installation Procedure
- Install the generator bracket.
- Install the generator bracket bolts.
Tighten: Tighten the bolts in the sequence shown.
- Tighten the generator bracket bolts (1, 2) to 50 N.m (37 lb ft).
- Tighten the generator bracket bolt (3) to 23 N.m (17 lb ft).
- Install the belt tensioner. Refer to Drive Belt Tensioner Replacement - Generator and Water Pump .
- Install the coolant inlet pipe lower bolt from the generator bracket.
- Install the generator. Refer to Generator Replacement (LC3) or Generator Replacement (LH2 w/AWD) or Generator Replacement (LH2 w/RWD) or Generator Replacement (LY7) .
NOTE:
Refer to Fastener Notice
.