LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2006 >> STS V >> Repair and Diagnosis >> External Pages >> Different car >> Section 156 (HVAC System - Automatic) >> Repair Instructions >> Blower Motor Control Processor Replacement (Left Hand Drive)

Blower Motor Control Processor Replacement (Left Hand Drive)

WARNING: This page is about a different car, the 2007 Cadillac SRX. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: View Of Blower Motor Control Processor (LHD)
GM1788800Courtesy of GENERAL MOTORS CORP.
Blower Motor Control Processor Replacement (Left Hand Drive)

Callout Component Name

Preliminary Procedure

  1. Remove right sound insulator. Refer to Instrument Panel Insulator Panel Replacement - Right Side (Left Hand Drive) or Instrument Panel Insulator Panel Replacement - Right Side (Right Hand Drive) .
  2. Remove the electrical connectors from the blower motor control processor.
1 Blower Motor Control Processor Screw (Qty: 2)
NOTE: Refer to Fastener Notice .

Tighten:  9 N.m (80 lb in)


 
2 Blower Motor Control Processor