Component Testing
- Lower the EVAP purge canister to gain access to the EVAP vent inlet, and seal it, using a suitable plug or a plug from the J 41413-300 . See Special Tools .
- Pressurize the EVAP system to 5 inches H20 with a J 41413-200 . See Special Tools .
- Compare the Fuel Tank Pressure sensor parameter with a scan tool to the J 41413-200 pressure/vacuum gage. See Special Tools . The scan tool FTP sensor parameter should be within 1 inch H20 of the pressure/vacuum gage.
- Remove the plug from the EVAP vent valve inlet.
- The scan tool Fuel Tank Pressure parameter should be 0 inches H20.
- If the FTP sensor parameters do not respond to the change in pressure, replace the FTP sensor.