Installation Procedure
- Connect the starter motor "S" terminal wire.
Tighten: Tighten the starter solenoid S terminal nut to 4 N.m (35 lb in).
- Connect the starter motor BAT terminal wire.
Tighten: Tighten the battery cable to starter terminal nut to 10 N.m (89 lb in).
- Install the starter motor.
- Install the starter motor mounting bolts.
Tighten: Tighten the starter motor mounting bolts to 30 N.m (22 lb ft).
- Install the intake manifold. Refer to Intake Manifold Replacement in Engine Mechanical-4.6L.
- Connect the battery negative cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
NOTE:
Refer to Fastener Notice in Cautions and Notices.