Installation Procedure
- Connect the electrical connectors to the HVAC control assembly.
- Install the HVAC control assembly.
- Install the accessory switch assembly to the instrument panel. Refer to Accessory Switch Replacement in Instrument Panel, Gages, and Console.
- Install the screws from the HVAC control assembly.
Tighten: Tighten the screws to 1.9 N.m (17 lb in).
- Install the instrument panel storage tray.
- Install the instrument cluster trim plate bezel. Refer to Bezel Replacement - Instrument Panel (I/P) Cluster in Instrument Panel, Gages, and Console.
- Start the vehicle and let run for one minute.
IMPORTANT:
The Key should be in the off position when connecting the electrical connectors to ensure proper calibration.
NOTE:
Refer to Fastener Notice in Cautions and Notices.
IMPORTANT:
Do not adjust any controls on the HVAC control module while the HVAC control module is calibrating.
If interrupted improper HVAC performance will result.
If interrupted improper HVAC performance will result.