Installation Procedure
- Install the blower motor control processor (2) to the HVAC module (1).
- Install the blower motor control processor retaining screws.
Tighten: Tighten the screws to 1.6 N.m (14 lb in).
- Connect the electrical connector (4) to the blower motor control processor (2).
- Connect the electrical connector at the blower motor.
- If equipped, install the sound insulator panel. Refer to Insulator Replacement - Instrument Panel (I/P) in Instrument Panel, Gages and Console.
NOTE:
Refer to Fastener Notice in Cautions and Notices.