  1. Did you perform the Diagnostic System check for engine Electrical? If so, go to next step. If not, go to ENGINE ELECTRICAL DIAGNOSTIC SYSTEM CHECK  .
  2. Turn OFF all electrical loads. Start the engine. Install a scan tool. With a scan tool view the IGNITION 1 SIGNAL PARAMETER in the PCM data list. Does the scan tool indicate the voltage is within the specified value of 11.0-15.5 V? If so, go to next step. If not, go to INTERMITTENTS  .
  3. Turn OFF the ignition. Connect a charging system tester to the battery (follow the manufactures instructions). Operate the engine at 2500 RPM. Adjust the carbon pile as necessary in order to obtain the maximum current output. Is the generator output within 10 A of the specified value of 98 A or above? If so, go to step  9 . If not, go to next step.
  4. Maintain the engine speed at 2500 RPM and continue to operate the generator at the load test value. Measure the voltage drop between the generator output terminal and the battery positive terminal. Is the voltage above the specified value of 0.5 V? If so, go to step  6 . If not, go to next step.
  5. Maintain the engine speed at 2500 RPM and continue to operate the generator at the load test value. Measure the voltage drop between the battery negative terminal and the generator metal housing. Is the voltage above the specified value of 0.5 V? If so, go to step  7 . If not, go to step  8 .
  6. Test the battery positive voltage circuit between the generator output terminal and the battery positive terminal for a high resistance. Did you find and correct the condition? If so, go to step  9 . If not, go to next step.