Test B: Charge Indicator Light Always On
- If diagnostic system check was not performed, perform ENGINE ELECTRICAL DIAGNOSTIC SYSTEM CHECK under SELF-DIAGNOSTIC SYSTEM. If diagnostic system check was performed, go to next step.
- Start engine. If charge indicator light remains illuminated after 5 second bulb check, go to next step. If charge indicator light does not remain illuminated after 5 second bulb check, problem is intermittent. Check wiring and connections.
- Install scan tool. Using scan tool, observe Battery Voltage parameter in Instrument Panel Cluster (IPC) data list. If voltage is 10-15 volts, go to next step. If voltage is not 10-15 volts, test primary generator. See TEST A: CHARGING SYSTEM TEST .
- Replace IPC. See ANALOG INSTRUMENT PANELS - DEVILLE article in ACCESSORIES & EQUIPMENT. After repair, go to next step.
- Operate system to verify repair. If system is not operating correctly, repeat test beginning at step 2 .