Charge Indicator Light Always On
NOTE:
Connector C102 (Brown), in circuit between instrument panel and generator, is located in left front of engine compartment, behind battery.
- Ensure starter is okay. See STARTERS article.
- Disconnect generator connector C2 (Blue/White wire). Turn ignition on. If indicator light illuminates, go to step 4). If indicator light does not illuminate, go to next step.
- Replace generator. Go to step 7).
- Disconnect connector C102. If indicator light is still illuminated, go to step 6). If indicator light goes out, go to next step.
- Locate and repair short in circuit between generator connector C2 and connector C102 terminal No. 3. Go to step 7).
- Locate and repair short in circuit between instrument panel connector terminal No. 18 and connector C102 terminal No. 3. If no short exists, replace instrument panel. Go to step 7).
- Reconnect all connectors and recheck indicator light. If light is not operating properly, go to step 1).