Pull-In Windings Test
Connect test equipment as in hold-in windings test. See HOLD-IN WINDINGS TEST. See Fig 1. Ground starter solenoid terminal "M". Turn switch on and quickly adjust carbon pile load until voltage reads as specified. See PULL-IN WINDINGS SPECIFICATIONS table. Check ammeter reading. Turn off carbon pile and open switch. See PULL-IN WINDINGS SPECIFICATIONS table. If ammeter reading is not as specified, replace starter solenoid.
PULL-IN WINDINGS SPECIFICATIONS
| Engine |
Starter Motor |
Amps |
| 4.6L |
PG250 |
60-85 |
| 4.6L |
PG260 |
30-50 |
Courtesy of GENERAL MOTORS CORP.