Master Control Switch
NOTE:
For terminal identification, see WIRING DIAGRAMS
.
Check for power at terminal "F" (Pink wire). All other switch terminals should have continuity to terminal "E"(Black wire) when all switches are in rest position. Operate switches and check continuity. See MASTER CONTROL SWITCH CONTINUITY . If continuity does not exist as specified, replace master control switch.
MASTER CONTROL SWITCH CONTINUITY
| Switch Position | (1) Terminals | |||
|---|---|---|---|---|
| Left Front | ||||
| Up | F & H | |||
| Down | F & G | |||
| Right Front | ||||
| Up | F & K | |||
| Down | F & J | |||
| Left Rear | ||||
| Up | F & B | |||
| Down | F & A | |||
| Right Rear | ||||
| Up | F & D | |||
| Down | F & C | |||
|
||||