Keyless Entry Programming
Perform the following when replacing Keyless Entry Module or either Transmitter
- Turn ignition switch to OFF position.
- Jumper ALDL terminal G (PPL/WHT) wire to terminal A (BLK/WHT) wire. Door locks will lock and unlock and trunk release will activate in approximately 2 seconds. See Fig 1 .
- Press any button on one transmitter. Door locks will lock and unlock and trunk release will activate in approximately 2 seconds. The first transmitter is now programmed.
- Repeat previous step with the other transmitter. If only one transmitter is being used, go to next step.
- Disconnect jumper from program connector.