Entering Diagnostics
Operating the vehicle in diagnostics for extended time periods without the engine running or without a battery charger will cause the battery to run down and possibly relate false diagnostic information, or cause a no start condition. To ensure proper operation, attach a battery charger if vehicle is to be operated in diagnostics without engine running for periods longer than 1/2 hour.
To enter diagnostic mode, turn ignition to ON position. Press "OFF" and "WARMER" buttons on the Climate control panel simultaneously, and hold until a segment check is displayed on IPC and COMBO panel. See Fig 1 and Fig 2 . If any or all segments do not display on the IPC and COMBO panel, go to SEGMENT CHECK FAILURE .