LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 1991 >> Allante 4T60/ME9 >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System >> Operation >> Fluid Level Sensor

Fluid Level Sensor

A fluid level sensor is included in the reservoir cap. This sensor consists of a float assembly which closes a switch when low fluid is detected. This signal is used as an input to the BCM and the EBCM. A low fluid input to the BCM will cause the LOW BRAKE FLUID message to be displayed on the CCDIC at key-on. The EBCM will disable anti-lock function and turn on the Red BRAKE warning lamp if a low fluid input is received. The fluid level sensor may be serviced as a part of the reservoir cap.