EXPERTEC TSB (T87-129)
Publication date: 1987-07-15Reference number: T87-129
EXPERTEC TSB
TECHNICAL SERVICE BULLETIN
Reference Number(s): T87-129, Date of Issue:
07/15/87
ERRATIC A/C COMP. OPERATION - POSSIBLE POWER STEERING SW.
Model(s): 1985-1987 Cimarrons
Bulletin No.: Cadillac T87-129
Date: 07/15/1987
SERVICE INFORMATION
Some 1985-1987 Cimarrons may experience erratic A/C compressor operation. This condition may be caused by a corroded power steering pressure switch. To diagnose this condition, disconnect the power steering pressure switch and jumper across the connector terminals while the compressor is operating erratically. If the compressor stops cycling erratically, replace the power steering pressure switch, P/N 10041728. Should the compressor continue to cycle erratically, refer to Section 6E2, Chart C-101, for 1985-86 2.OL or Section 6E3, Chart C-10A, for 1985-87 2.8L.
For warranty purposes, use Labor Operation D1113 at .3 hours.