Automatic Temperature Control: Adjustments
Three adjustments are possible and may be necessary in case of malfunctioning of the Automatic Temperature Control System, The adjustments are:
- Temperature Dial Calibration.
- Air-Mix Door adjustment.
- Feedback Potentiometer adjustment.
Correct settings to obtain proper adjustment requires the use of the specialized ATC Tester J-23678. Instructions to accomplish adjustments accompany the Tester.