LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2020 >> Envision Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 97 (Cellular System, Entertainment System, And Navigation System - Diagnostic Information And Procedures) >> Diagnostic Information and Procedures >> Auxiliary Audio Input Malfunction (IO5/IO6) >> Circuit/System Testing >> Front Console USB Ports

Front Console USB Ports

WARNING: This page is about a different car, the 2018 Buick Regal TourX and 2018 Buick Regal. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the X1 harness connector at the X92 USB Receptacle.
  2. Test for less than 10 Ω between the ground circuit terminal 4 and ground.
    • If 10 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • Go to next step: If less than 10 Ω 
  3. Verify that a test lamp illuminates between the B+ circuit terminal 6 and ground.
    • If the test lamp does not illuminate 
    1. Ignition OFF, remove the test lamp.
    2. Test for less than 2 Ω in the B+ circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
    • Go to next step: If the test lamp illuminates 
  4. Verify the USB cable is properly connected at all components and in-line connections, and there is no damage to the cable or connections.
    • If connection problems or cable damage is noted. 

      Perform the appropriate repair or replacement to correct any issues.

    • Go to next step: If no connection problems or cable damage is noted. 
  5. Connect the X1 harness connector at the X92 USB Receptacle.
  6. Disconnect the vehicle USB cable X4 harness connector at the K74 Human Machine Interface Control Module and the X92 USB Receptacle.
  7. Connect the EL-50034 - 14 Infotainment Test Cable and the EL-50334 - 2 Type-A Female to Mini-B Male Cable together. Connect the assembled test cable to the K74 Human Machine Interface Control Module and the X92 USB Receptacle.
  8. Ignition ON, infotainment system ON.
  9. Connect the EL-50334-20 Multi-Media Interface Tester (MIT) to the X92 USB Receptacle USB port and select the USB test mode.
  10. Verify the audio from the EL-50334-20 Multi-Media Interface Tester (MIT) is heard through the infotainment system while operating the system to play audio from the test tool.
    • If audio is not heard from the test tool 
    1. Replace the X92 USB Receptacle. Connect all harness connectors.
    2. Connect the EL-50334-20 Multi-Media Interface Tester (MIT) to the X92 USB Receptacle USB port and select the USB test mode.
    3. Verify the audio from the EL-50334-20 Multi-Media Interface Tester (MIT) is heard through the infotainment system while operating the system to play audio from the test tool.
      • If audio is not heard from the test tool, replace the K74 Human Machine Interface Control Module.
      • Go to next step: If audio is heard from the test tool.
    4. All OK.
    • Go to next step: If audio is heard from the test tool 
  11. Replace the USB cable assembly.