K74 Human Machine Interface Control Module X1
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | 13575742 | J-35616-64B (LT BU) | J-38125-215A | Not Available | Not Available | Not Available | Not Available |
| II | 13575867 | J-35616-64B (LT BU) | J-38125-215A | Not Available | Not Available | Not Available | Not Available |
| III | Not Required | J-35616-64B (LT BU) | No Tool Required | Not Available | Not Available | Not Available | Not Available |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.35 | GY/YE | 5149 | Voice Recognition Audio Signal | II | - |
| 2 | 0.35 | BK/GY | 5152 | Voice Recognition Audio [-] Control | II | - |
| 3 - 4 | - | - | - | Not Occupied | - | - |
| 5 | 0.5 | WH/BU | 5986 | Serial Data Communication Enable | I | - |
| 6 | - | - | - | Not Occupied | - | - |
| 7 | 0.35 | RD/YE | 5040 | Secondary Fused Battery Positive Voltage 50 | II | IO5/IO6 |
| 8 | 0.35 | BK | 1750 | Ground 17 | II | IO5/IO6 |
| 9 | 0.35 | GN/WH | 7527 | Human Machine Interface Control Module LIN Bus 1 | II | - |
| 10 | - | - | - | Not Occupied | - | - |
| 11 | 0.5 0.35 |
BU/GN BU |
1304 2500 |
High Speed GMLAN Serial Data [+] 9 High Speed GMLAN Serial Data [+] 1 |
I III |
IO5 -UE1 |
| 12 | 0.5 0.35 |
WH/GN WH |
1305 2501 |
High Speed GMLAN Serial Data [-] 9 High Speed GMLAN Serial Data [-] 1 |
I III |
IO5 -UE1 |
| 13 | 0.35 | BU/GN | 1304 | High Speed GMLAN Serial Data [+] 9 | II | IO5/IO6 |
| 14 | 0.35 | WH/GN | 1305 | High Speed GMLAN Serial Data [-] 9 | II | IO5/IO6 |
| 15 - 16 | - | - | - | Not Occupied | - | - |