Circuit/System Testing
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the appropriate electrical connector: A24D Door Handle Assembly - Driver ExteriororA24P Door Handle Assembly - Passenger Exterior
- Test for less than 10 ohms between the test points: Ground circuit terminal 5 & Ground
- If 10 ohms or greater
- Ground Connection - Disconnect
- Test for less than 2 ohms between the test points: Ground circuit terminal 5 @ Component harness & Ground Connection
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Repair the open/high resistance in the ground connection.
- Go to next step: If less than 10 ohms
- Ignition - On / Vehicle - In Service Mode
- Verify the scan tool parameter: Exterior Door Handle Switch Circuit = Inactive
- If not the specified state
- Ignition/Vehicle - Off
- Disconnect the electrical connector: X2 @ K84 Keyless Entry Control Module
- Test for infinite resistance between the test points: Signal circuit terminal 1 @ Component harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: K84 Keyless Entry Control Module
- Go to next step: If the specified state
- Connect a 3 A fused jumper wire between the test points: Signal circuit terminal 1 & Ground circuit terminal 5
- Verify the scan tool parameter: Exterior Door Handle Switch Circuit = Active
- If not the specified state
- Ignition/Vehicle - Off & Remove - Jumper wire (s)
- Disconnect the electrical connector: X2 @ K84 Keyless Entry Control Module
- Ignition - On / Vehicle - In Service Mode
- Test for less than 1 V between the test points: Signal circuit terminal 1 @ Component harness & Ground
- If 1 V or greater - Repair the short to voltage on the circuit.
- Go to next step: If less than 1 V
- Ignition/Vehicle - Off
- Test for less than 2 ohms between the test points:
- Signal circuit terminal 1 @ A24D Door Handle Assembly - Driver Exterior & Terminal 12 X2 @ Control module harness
- Signal circuit terminal 1 @ A24P Door Handle Assembly - Passenger Exterior & Terminal 11 X2 @ Control module harness
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Replace the component: K84 Keyless Entry Control Module
- Go to next step: If the specified state
- Test or replace the component: A24 Door Handle Assembly
NOTE:
It may take up to 2 min for all vehicle systems to power down before an accurate ground or low reference circuit continuity test can be performed.