K171 Hands-Free Liftgate Sensor Control Module X1 (W49+TC2)
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Required | J-35616-16 (LT GN) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.5 | GN/BN | 4118 | Local Interconnect Network Serial Data Bus 18 | I | - |
| 2 | 0.5 | RD/WH | 1340 | Battery Positive Voltage | I | - |
| 3 | 0.5 0.5 |
BK/WH BK/WH |
151 151 |
Signal Ground Signal Ground |
I I |
UKC -UKC |