LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2017 >> Envision Preferred, AWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Diagnostic Information and Procedures >> DTC P058A-P058F, P16D4-P16D6, P16DC-P16DF, or P16E1-P16E3: Battery Sensor Module >> Circuit/System Verification

Circuit/System Verification

  1. Ignition OFF, measure and record the battery voltage at the battery terminals.
  2. Verify the battery voltage stabilizes between 12.4 and 12.8 V within a few minutes of turning the ignition OFF.
    • If battery voltage is between 12.4 and 12.8 V 
  3. Engine running, headlights ON, measure and record the battery voltage at the battery terminals.
  4. Verify the voltage is at least 1 V greater than the voltage measured in step 1, but less than 15 V.
    • If the voltage is not at least 1 V greater than the voltage measured in step 1 or is greater than 15 V. 

      Refer to Charging System Test .

    • If the voltage is at least 1 V greater than the voltage measured in step 1, but less than 15 V. 
  5. Refer to Circuit/System Testing.