Component Testing
Relay Test
- Ignition OFF, disconnect the appropriate relay.
- Test for 60 - 200 Ω between terminals 1 and 2.
- If less than 60 or greater than 200
Replace the relay.
- If between 60 - 200 Ω
- If less than 60 or greater than 200
- Test for infinite resistance between the terminals listed below:
- 3 and 2
- 3 and 5
- 3 and 2
- 2 and 5
- If less than infinite resistance
Replace the relay.
- If infinite resistance
- Test for less than 5 Ω between terminals 3 and 4.
- If 5 Ω or greater
Replace the relay.
- If less than 5 Ω
- If 5 Ω or greater
- Install a 10 A fused jumper wire between relay terminal 1 and 12 V. Install a jumper wire between relay terminal 2 and ground.
- Test for less than 5 Ω between terminals 3 and 5.
- If 5 Ω or greater
Replace the relay.
- If less than 5 Ω
- If 5 Ω or greater
- All OK