LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2017 >> Envision Base >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System - Automatic >> Diagnostic Information and Procedures >> DTC B0223, B022A, B0233, B023A, B0408, B0418, B0428, or B3531: Recirculate Position Command/Air Flow Control/Air Flow Control/Temperature Control/Rear Air Flow Control >> Circuit/System Description

Circuit/System Description

Stepper motors are used for temperature regulation, air distribution control and recirculation door control.

With the switches and dials on the HVAC controls, air temperature door position, mode door position and recirculation door position can be selected. The selected values are passed to the HVAC control module via serial data. The HVAC control module supplies a 12 V reference voltage to the stepper motors and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motors move the appropriate doors into the calculated positions, in order to reach the desired positions.