LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2016 >> Encore Base, FWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Description and Operation >> Charging System Description and Operation >> Battery Sulfation Mode

Battery Sulfation Mode

The BCM will enter this mode when the interpreted generator output voltage is less than 13.2 V for 45 minutes. When this condition exists the BCM will enter Charge Mode for 2-3 minutes. The BCM will then determine which mode to enter depending on voltage requirements.