Charging System Operation
The purpose of the charging system is to maintain the battery charge and vehicle loads. There are 6 modes of operation and they include:
- Battery Sulfation Mode
- Charge Mode
- Fuel Economy Mode
- Head lamp Mode
- Start Up Mode
- Voltage Reduction Mode
The engine control module (ECM) controls the generator through the generator turn ON signal circuit. The ECM monitors the generator performance though the generator field duty cycle signal circuit. The signal is a pulse width modulation (PWM) signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-95 percent. Between 0-5 percent and 95-100 percent are for diagnostic purposes. The following table shows the commanded duty cycle and output voltage of the generator:
| Commanded Duty Cycle | Generator Output Voltage |
|---|---|
| 10% | 11 V |
| 20% | 11.56 V |
| 30% | 12.12 V |
| 40% | 12.68 V |
| 50% | 13.25 V |
| 60% | 13.81 V |
| 70% | 14.37 V |
| 80% | 14.94 V |
| 90% | 15.5 V |
The generator provides a feedback signal of the generator voltage output through the generator field duty cycle signal circuit to the ECM. This information is sent to the body control module (BCM). The signal is PWM signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-99 percent. Between 0-5 percent and 100 percent are for diagnostic purposes.