Generator Pulley Replacement
| Callout | Component Name |
|---|---|
| Preliminary Procedure Remove the generator. Refer to Generator Replacement . |
|
| 1 | Generator Pulley Nut Cap |
| 2 | Generator Pulley
CAUTION:
Refer to Fastener Caution . Procedure Remove the generator pulley nut by using EN-6372 counterhold.
NOTE:
Be aware of the left-hand thread. Tighten 80 N.m (59 lb ft) Special Tools EN-6372 Counterhold For equivalent regional tools, refer to Special Tools . |