Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the appropriate door actuator, ignition ON.
- Connect a test lamp between the B+ circuit terminal 2 and ground.
- Verify the test lamp turns ON and OFF repeatedly when commanding the actuator ON but not OFF with a scan tool.
- If the test lamp is always OFF
- Ignition OFF, disconnect the harness connector at the K33 HVAC control module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K33 HVAC control module.
- If the test lamp is always ON
- Ignition OFF, disconnect the harness connector at the K33 HVAC control module, ignition ON.
- Test for less than 1 V between the control circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V, replace the K33 HVAC control module.
- If the test lamp turns ON and OFF
- Connect a test lamp between each actuator harness connector terminal listed below one at a time and B+.
- Control Circuit - terminal 1
- Control Circuit - terminal 3
- Control Circuit - terminal 4
- Control Circuit - terminal 6
- Verify the test lamp turns ON and OFF repeatedly when commanding the actuator ON but not OFF with a scan tool.
- If the test lamp is always OFF
- Ignition OFF, disconnect the harness connector at the K33 HVAC control module, Ignition ON.
- Test for less than 1 V between the control circuit and ground.
- If less 1 V or greater, repair the short to voltage on the circuit.
- Ignition OFF
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K33 HVAC control module.
- If the test lamp is always ON
- Ignition OFF, disconnect the harness connector at the K33 HVAC control module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K33 HVAC control module.
- If the test lamp turns ON and OFF
- Replace the appropriate HVAC door actuator.