  1. Check the cooling system for the correct amount of coolant. Refer to Cooling System Draining and Filling (Static Fill) , Cooling System Draining and Filling (GE 47716) .
  2. Verify that DTC P0A2C, P0CC1-P0CC4 is not set.
  3. Start the engine and observe the scan tool motor A calculated rotor temperature parameter. The reading should be less than 180°C (356°F). If greater than the specified value, check the cooling system and pump for proper operation. If there is coolant and flow then monitor the calculated rotor temperature and verify that it drops below 180°C (356°F). If the temperature does not drop below 180°C (356°F) then reprogram the K59 starter generator control module. If the DTC resets, replace the K59 starter generator control module.