Circuit/System Testing
- Ignition OFF, disconnect the KR5 rear defogger relay.
- Test for less than 10 Ω between the ground circuit terminal 85 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance
- Connect a test lamp between the control circuit terminal 86 and the ground circuit terminal 85.
- Engine running, command the E18 rear window defogger grid ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K33 HVAC control module.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K33 HVAC control module.
- If all circuits test normal, test or replace the KR5 rear defogger relay.