Component Testing
Relay Test
- Ignition OFF, disconnect the RUN/CRANK relay.
- Test for 60-180 ohms between terminals 85 and 86.
- If the resistance is not within the specified range, replace the relay.
- Test for infinite resistance between the following terminals:
- 30 and 86
- 30 and 87
- 30 and 85
- 85 and 87
- If less than infinite resistance, replace the RUN/CRANK relay.
- Install a 20-amp fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground. Test for less than 2.0 ohms between terminals 30 and 87.
- If greater than 2.0 ohms, replace the RUN/CRANK relay.