Removal Procedure

    Fig 1: Identifying Negative Battery Cable Terminal & Battery
    GM1616995Courtesy of GENERAL MOTORS CORP.
  1. Disconnect the instrument panel (I/P) harness electrical connector (2) from the battery current sensor.
  2. Remove the positive and negative battery cable. Refer to Battery Positive and Negative Cable Replacement (LS4) .
  3. Fig 2: Identifying Battery Current Sensor & Battery Cable
    GM1617007Courtesy of GENERAL MOTORS CORP.
  4. Cut the tie straps and electrical tape attaching the battery current sensor to the positive battery cable.
  5. Squeeze the battery cable branches together.
  6. IMPORTANT: Note the position of the battery current sensor prior to removal.
  7. Slide the battery current sensor (1) off of the battery cable.