Removal Procedure
- Remove the case side cover. Refer to Case Side Cover Replacement .
- Use a flat-bladed tool to disconnect the electrical connectors from the solenoid valves (315A, 315B, 322, 334 and 440), the TFP manual valve position switch (395) and the temperature sensor (391).
- Remove the oil pump bolts (206,207).
- Remove the oil pump (200) from the valve body (300).
IMPORTANT:
Do NOT remove the bolt (205) that holds the oil pump together.