Installation Procedure
- Connect the electrical connectors.
- Install the HVAC control module.
- Install the HVAC control module mounting screws.
Tighten: Tighten the screws to 2 N.m (18 lb in).
- Install the front floor console. Refer to Console Replacement - Front Floor in Instrument Panel, Gages, and Console.
- Start the engine and run for one minute.
IMPORTANT:
The key should be in the off position when connecting the electrical connectors to ensure proper calibration.
NOTE:
Refer to Fastener Notice in Cautions and Notices.
IMPORTANT:
Do not adjust any controls on the HVAC control module while the HVAC control module is calibrating. If interrupted improper HVAC performance will result.