Removal Procedure
Courtesy of GENERAL MOTORS CORP.
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
- Remove the drive belt from the generator. Refer to Drive Belt Replacement
in Engine Mechanical - 3.1L.
- Place the coolant recovery reservoir aside for access. Refer to Coolant Recovery Reservoir Replacement
in Engine Cooling.
- Remove the generator rear brace nut (4).
- Remove the bolts (1, 2, 3) from the generator.
- Disconnect the electrical connector from the generator.
- Remove the protective boot from the generator output BAT terminal.
- Remove the generator output BAT terminal nut and remove the positive battery lead from the generator.
- Remove the generator.