LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2004 >> Century Custom >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Repair Instructions >> Generator Replacement (3.1L) >> Removal Procedure

Removal Procedure

    Fig 1: Generator & Bolts (3.1L)
    GM302473Courtesy of GENERAL MOTORS CORP.
  1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
  2. Remove the drive belt from the generator. Refer to Drive Belt Replacement in Engine Mechanical - 3.1L.
  3. Place the coolant recovery reservoir aside for access. Refer to Coolant Recovery Reservoir Replacement in Engine Cooling.
  4. Remove the generator rear brace nut (4).
  5. Remove the bolts (1, 2, 3) from the generator.
  6. Disconnect the electrical connector from the generator.
  7. Remove the protective boot from the generator output BAT terminal.
  8. Remove the generator output BAT terminal nut and remove the positive battery lead from the generator.
  9. Remove the generator.